- Diagnostics
- Monday, 16 Dec 2019
FDA Approves Diffusion-Weighted Images for Elekta Unity, Expanding Options for Assessment During Therapy
Elekta (EKTA-B.ST) today announced that it has received 510(k) premarket notification from the U.S. Food and Drug Administration for the use of diffusion-weighted MR images (DWI) obtained with Elekta Unity to be interpreted by a trained physician. This expands the clinical utility of Elekta Unity to include biologic assessment of tumor response during therapy, allowing treatment adaptation based not just on gross anatomic changes but also on early biologic changes at the cellular level. Elekta Unity, the world's first high-field MR-Linac, received initial 510(k) clearance in December 2018 and CE mark in June 2018.
DWI creates a map of the diffusion of water molecules at the cellular level and can be processed to generate the apparent diffusion coefficient, or ADC. A growing body of evidence shows that ADC changes within a tumor can provide important insights into an individual's tumor response that would previously have been unavailable during radiation treatment. These insights can support further personalization of the radiation therapy regimen by allowing more tailored dose adaptation. The acquisition of DWI is critically dependent on the high quality of the 1.5 Tesla MR scanner integrated into Elekta Unity and can occur while the patient is undergoing their treatment with little or no overhead.
"One of the goals for Elekta Unity was to develop an MR-guided radiation therapy system that not only treats patients with unparalleled anatomic personalization but could also incorporate the individuals' response to their treatment.," said Richard Hausmann, President and CEO, Elekta. "This new functionality has excited early adopters of Unity. It allows us to assess biologic changes within the tumor, which may occur earlier than anatomic changes. This will improve clinicians' ability to deliver the right dose to the right part of the tumor based on this new biological marker.
As a result of this 510(k) clearance, the Indication of Use Statement for Elekta Unity has been updated to include the following language: When interpreted by a trained physician magnetic resonance images acquired before, during, and after the radiotherapy treatment yield information that can be useful in diagnosis and may assist therapy planning, patient positioning and treatment delivery related to radiation oncology.
In addition to the comprehensive MRI sequences cleared with the initial release, Elekta Unity now has the ability to generate images using the following techniques, before, during or after treatment for off-line review:
- Single-shot EPI diffusion imaging (DWI) with three diffusion directions and up to 16 b-values.
- Diffusion imaging processing with automatic generation of the ADC and/or eADC maps.
Related Industry Updates
Curavit Clinical Research officially launches with a focus on virtual trials
Feb 18, 2020
Hangzhou Realy IgG/IgM Rapid Test Device Deployed to Global Market
May 11, 2020
Epidemic in the UK is slowing and antibody test could be ready in days, top epidemiologist says
Mar 30, 2020
North America Anti-Viral Therapies Market Growth Focusing on Trends & Innovations During the Period Until 2027
Dec 18, 2020
Sepsis Diagnostics: Early Detection Saves Lives
Feb 17, 2026
QuEST Global Enhances its Lung Nodule Detection Solution Using Microsoft Azure IoT Central, Azure IoT Edge and Azure Machine Learning
Jun 12, 2020
$4.6m Awarded for Clinical Trials at Northwell's Cancer Institute
Oct 16, 2019